DESCRPTION
CO2 incubator with additional process controls
The BINDER CB series CO2 incubator is the premium class among the CO2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CO2 incubator of the CB series is up to even complex cultivation experiments or individual environments.
Advantages:
- Hot air sterilization at 180 °C
- Seamless, deep-drawn inner chamber made of stainless steel
- Unique BINDER technology (patented air jacket system, controlled condensation, etc.)
Areas of application:
Features |
Customer benefits |
Characteristics |
Sterilization |
- Complete elimination of bacteria, spores, etc.
- Reliable sterilization of the atmosphere and all surfaces
- Minimal sterilization costs
|
180 °C hot air sterilization
- Standards compliance, meets all relevant standards
- Automatic sterilization process
|
Permadry™ humidity system |
- Uniform osmotic cell pressure
- Optimum cell growth even with microwell plates
- No Provides no sources of contamination.
|
Controlled humidification system
- Defined recondensation point
- Dry interior walls
- High humidity
- Rapid humidity recovery times
- Simple water exchange through water pan
|
APT.line™ heating technology |
- Optimal, uniform cell growth throughout the inner chamber
|
Preheating chamber with VENTAIR™ air jacket
- Homogeneous temperature distribution
- Rapid recovery after temperature drop
- Accurate temperature control
|
Gas distribution |
|
Gas mixing head with venturi effect
- Homogeneous CO2 distribution
- Fast effective aeration
|
Inner chamber concept |
- Easy cleaning
- Fully usable volume 53, 150, 210 l
- No Provides no sources of contamination.
|
Seamless, deep-drawn inner chamber
- Integrated shelf support system
- Burr-free stainless steel perforated sheets with tilt protection
|
CO2 measurement |
- Stable pH value even with frequent door opening
- Long-term stable system
- Low maintenance costs
|
Single-beam infrared sensor
- Rapid response time
- Measures CO2 in real-time
- Independent of gas and humidity
|
Operating costs |
- Minimal operating costs
- Time savings
|
- Minimal work and material costs for sterilization
|
Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and best cell growth
- Temperature range from 7 °C above ambient temperature to 60 °C
- MCS controller for temperature and CO2 concentration
- User-friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real time clock
- Standard-compliant hot air sterilization at 180 °C (DIN 58947)
- VENTAIR™ Jacket System
- Drift-free infrared CO2 measurement system
- Patended Gas mixing nozzle
- Permadry System – condensation-free double-pan humidification system, maintains dry interior walls
- Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges)
- Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring
- Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
- Tightly-fitted inner glass door
- RS 422 interface for communication software APT-COM™ DataControlSystem
- 2 perforated stainless steel shelves with standard equipement and O2 control
- Units are stackable with stacking adapter
- Door lock
- BINDER test confirmation
CB 53 |
|
Exterior dimensions |
|
|
Width (mm) |
580 |
|
Height (incl. feet) (mm) |
720 |
|
Depth (plus 55 mm for door handle and connection) (mm) |
550 |
|
Wall clearance side / rear (mm) |
50 / 100 |
|
Number of doors (ea.) |
1 |
|
Inner glass door(s) |
1 |
|
|
|
|
Interior dimensions |
|
|
Width (mm) |
400 |
|
Height (mm) |
400 |
|
Depth (mm) |
330 |
|
Interior volume (l) |
53 |
|
Number of shelves (standard/max.) |
2 / 3 |
|
Dimensions shelves width x depth (mm) |
396 x 289 |
|
Load per shelf (kg) |
10 |
|
Permitted total load (kg) |
30 |
|
Weight (empty) (kg) |
60 |
|
|
|
|
Temperature data |
|
|
Temperature range from 5 °C above ambient temperature to (°C) |
60 |
|
Temperature variation at 37 °C (± K) |
0,3 |
|
Temperature fluctuation at 37 °C (± K) |
0,1 |
|
Recovery time after door was opened for 30 sec. at 37 °C (min.) 1) |
3 |
|
|
|
|
Humidity data |
|
|
Humidity (±2% r.h.) |
95 |
|
|
|
|
CO2 data |
|
|
CO2 range (vol. % CO2) |
0 – 20 |
|
Setting accuracy (Vol.-% CO2) |
0,1 |
|
Recovery time after door was opened for 30 sec. 1) |
|
|
at 5.0 vol. % CO2 (min.) |
6 |
|
CO2 measurement |
IR |
|
Connection hose nozzle for CO2 for hose with internal diameter (mm) |
6 |
|
|
|
|
O2 data |
|
|
O2 range (vol. % O2) |
0,2 – 95 |
|
Setting accuracy (Vol.-% O2) |
0,1 |
|
Recovery time after door was opened for 30 sec. 1) |
|
|
at 1.0 vol. % O2 (min.) |
25 |
|
at 5.0 vol. % O2 (min.) |
9 |
|
O2 measurement |
ZrO2 |
|
Connection hose nozzle for O2 / N2 for hose with internal diameter (mm) |
6 |
|
|
|
|
Electrical data |
|
|
Voltage (± 10%) 50/60 Hz (V) |
230 |
|
Nominal power (kW) |
1,0 |
|
Energy consumption at 37 °C (W) 2) |
70 |
1) up to 98 % of the set value
2) These values can be used for dimensioning air condition systems.
Reviews