COMPANY: HARVARD ENGLAND

SOM CODE                                  MODEL                DESCRIPTION                                                                                  CATALOGUE                         
D431/216 & D501/22 76-0113 HOT PLATE THERMAL ANALGESY METER DOES NOT

INCLUDE SE DA COM SOFTWARE (RS232 COMM.)

→ Digital setpoint
→ Built-in electronic timer
→ Footswitch timing operation
→ Computer interface
Specification
→ Material Composition: Clear Methacrylate (animal holder), and aluminum (plate)
→ Maximum Number of Stations: 1 per computer (multiple sets available by request)
→ Power Requirements: 110/220V, 50/60Hz
→ Certification: CE
→ SeDaCom Included: Yes
→ Reaction Time : 3 digits, 0.01 sec increments
→ Operating Temperature: 45 to 62¡ C, 0.1 steps

COMPANY: UGO BASILE ITALY

SOM CODE         MODEL             DESCRIPTION                                                                                                                       CATALOGUE                 
D97/15 35100 HOT / COLD PLATE COMPLETE WITH DEDICATED DATA

ACQUISITION SOFTWARE 52050-11 SERIAL AND USB

OUTPUT, MEMORY KEY UNIVERSAL INPUT 85-264 VAC 50-

60HZ

Features
→ Operating Temperature: 2°C to 66°C presettable by function keys
→ Two operating modes: fixed or ramping temperature, for dynamic experiments
→ PC Interface: USB
→ Computer compatibility: direct connection to a PC, via the dedicated software included as standard
→ Data Portability: via the USB Memory-Key, included in the standard package
→ Print-out: by optional thermal MiniPrinter

Hot Plate Analgesia Meter
COMPANY: HARVARD, ENGLAND.

The Harvard Apparatus UK Hot Plate Analgesia Meter is sophisticated temperature control and timing system and has been designed to perform rapid and precise screening of the narcotic type analgesic drugs (Morphine, Codeine, etc.) according to the Eddy and Leimbach hot plate test. This method evaluates the reaction time of mice when a heat stimulus is applied to the plantar surface. This reaction time increases when a central analgesic is administered to the animal. This system can be used with both mice and rats. Utilizing a simple user interface the user can quickly and easily set up the required hot plate temperature and a large easy to read LED display shows the current temperature. The timer requires a single press of the Start / Stop key to start and another press to stop, with reset automatically executed when the timing is initiated. This function is also duplicated by a remote Start/Stop footswitch (supplied).

SOM CODE         Model              Description                                                                                                           Catalogue                                        
D501/38 52-8588 Hot Plate Analgesia Meter 220 to 230 VAC, 50 Hz
D341/16 52-8570 Hot Plate Analgesia Meter 110 to 115 VAC, 60 Hz
Temperature Range 35° to 65°C
Temperature Stability ±0.3°C
Temperature Control Digital proportional PWM
Timer Digital readout in 0.1 sec increments
Timer Range 0 to 9 mins 59 secs 9 tenths of a sec
Remote Momentary make to start/stop
Remote Socket 6.35 mm 2 pole jack
Animal Container Two furnished, large round cylinders
Mains Supply Voltage 115 VAC / 230 VAC, 50/60 Hz (factory set)
Dimensions, H x W x D 128 x 275 x 293 mm (5 x 10.8 x 11.5 in)
Weight 4.5 kg (9.9 lb)

COMPANY: UGO BASILE, ITALY.

SOM CODE           MODEL             DESCRIPTION                                                                                                        CATALOGUE                            
D97/12 37360 TAIL FLICK UNIT, NEW MICROPROCESSOR CONTROLLED

MODEL, COMPLETE WITH COMMUNICATION SOFTWARE

SERIAL AND USB OUTPUT, MEMORY KEY, UNIVERSAL INPUT

85-264 VAC 50-60HZ

The Ugo Basile Tail Flick has been designed to accurately measure the nociceptive threshold to infrared heat stimulus on the rat or mouse tail. The operator starts the stimulus and when the animal feels pain and flicks its tail, a sensor detects it, stops the timer, and switches off the bulb. The reaction time of the animal is thus determined automatically.

→ Automatic detection of the animal response
→ Data portable to a memory stick or to PC (USB)
→ Comfortable, unobstructed working surface (no protruding elements)
→ Excellent reproducibility due to optics lodged into a rigid structure & electronically controlled I.R. flux

Tail Flick Analgesia Meter
COMPANY: HARVARD, ENGLAND.

This meter measures a rat’s reaction time to radiant energy, from a 150 watt light source. The beam is focused on its tail using a parabolic reflector. The energy of the light source can be adjusted and the display indicates, as a percentage, how much energy is being utilized. An optical sensor is located underneath the focused light source. The rat should be positioned such that its tail obscures the focused light source from the sensor. When the system is started, either using the supplied footswitch or front panel mounted start key the light source illuminates and a timer starts counting in tenths of a second. When the rat’s tail flicks, indicating its pain threshold, it uncovers the sensor. This tail movement turns off the timer and light source. Reaction time can be read directly from the display in seconds and tenths of a second. A standard parallel port permits connection to a printer to record the trial number, energy level and reaction time. A calibration facility allows the light source to be set to the desired level before commencing with the experiment. Mouse version is also available. Please contact Harvard Apparatus for details

SOM CODE            MODEL                 DESCRIPTION                                                                                         CATALOGUE                                    
D501/37 52-9495 Tail Flick Analgesia Meter
Lamp Intensity 35° to 65°C
Printer Interface Centronix parallel
Lamp Heat Control Digital DC regulated
Timer Digital readout in 0.1 sec increments
Timer Range 0 to 99 min 59.9 secs in 0.1 sec steps
Dimensions, H x W x D 260 x 450 x 260 mm (10 x 18 x 10 in)
Weight 9 kg (19.8 lbs)

Tail Flick Meter for Evaluating Thermal Angalgesia
COMPANY: HARVARD ENGLAND

SOM CODE        Model       Description                                                                                                                                        Catalogue                         
D341/220 76-0293 TAIL FLICK HEAT BEAM ANALGEST METER SE DA COM SOFTWARE (RS232

COMM)NIT INCLUDED

D341/221 76-0294 THERMOMETER FOR LE7106 TAIL FLICK

→ Optimal detection due to the perfect alignment of heat stimulus and photo beam trigger
→ Photo beams with adjustable sensitivity
→ A light beam shows the point on which the heat source will focus
→ Manual and remote timer
→ Groove for correct tail placement
→ Automatic cut-off
→ Computer interface

COMPANY: HARVARD ENGLAND

SOM CODE            MODEL              DESCRIPTION                                                                                                    CATALOGUE                                   
D101/73 72-6703 HEAT FLUX IR RADIOMETER

The Heat-Flux Infrared Radiometer has been designed to calibrate I.R. sources, in particular the classic Plantar Test, to make sure they deliver the same power flux and hence a nociceptive stimulus of the same intensity.

→ Calibrates the Infrared emission of Plantar Test
→ Digital display
→ Takes only seconds to use
The Heat-Flux Infrared Radiometer has been designed to calibrate I.R. sources, in particular the classic Plantar Test, to make sure they deliver the same power flux and hence a nociceptive stimulus of the same intensity. This Heat-Flux Infrared Radiometer is a battery-operated, self-sufficient instrument complete with infrared probe, digital meter, and adaptors for the Plantar Test.

Plantar Test
COMPANY: HARVARD ENGLAND

SOM CODE                MODEL                       DESCRIPTION                                                                                      CATALOGUE                                     
D501/35 72-6693+72-6683 PLANTAR TEST 230V + 6 CH MULTI PRINTER 230V
D101/72 72-6692 PLANTAR TEST (HARGREAVES)

Controller, Emitter/Detector Vessel, complete with cable, Platform with supporting columns, Framed Glass Pane, Three-Compartment Rat Enclosure, Spare Bulb, Mains Cable, Instruction Manual, 1.5 mm Allen Wrench, Dust Cover, and Set of Fuses for 230 V operation or 115 V operation.

→ For measurement of hyperalgesia to thermal stimulation in unrestrained animals
→ Automatic detection of the behavioral end point
→ Validity unaffected by repeated testing
→ Greater bioassay sensitivity than other thermal or mechanical tests
→ Each animal can serve as its own control

COMPANY: HARVARD ENGLAND

SOM CODE               MODEL            DESCRIPTION                                                                                                   CATALOGUE                                   
D145/32 64-1555 HIDR F/SOLUTION HTRS SH27 SF28

An ideal tool for holding Warner In-line Solution Heaters close to the chamber. Machined from a solid Delrin block, these sturdy holders can be secured to your microscope stage using gaffer or duct tape.

→ The SHH-1 works with both our SH-27B and SF-28 Solution Heaters.
→ The SHH-2 mounts our SC-20 In-line Solution Heater/Cooler.
→ The SHH-3 is used for the SHM-6, SHM-8, and SHM-828 Multiline In-line Heaters.
→ The SHH-4 works with our FR-50 and FR-55S flow valves.

SOM CODE         Model                  Company                                         Description                                                                                                               
D97/144 E-HR OO4 UGO BASILE ITALY UGOBAS/1-2/NH/MUS/KH,PELTIER 40x40x4,7 12VDC,34W
D341/213 76-0406 HARVARD SPAIN SEDACOM SOFTWARE

Note: Please mention the product “SOM CODE” while making a request for quotation and send it to *****@somatco.com