SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/816 | HI3817 | WATER QUALITY TEST KIT COMPLETE |
Water Quality Test Kit – Accurate and Reliable Water Quality TestsNew
COMPANY: HANNA ROMANIA
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/816 | HI3817 | WATER QUALITY TEST KIT COMPLETE |
The Hanna HI3817 combination test kit offers all the necessary equipment for accurate and reliable water quality testing.
→ Alkalinity (as CaCO3) – 0-100 mg/L (ppm) | 0-300 mg/L (ppm)
→ Chloride – 0-100 mg/L (ppm) | 0-1000 mg/L (ppm)
→ Hardness (as CaCO3) – 0.0-30.0 mg/L (ppm) | 0-300 mg/L (ppm)
→ Iron – 0-5 mg/L (ppm)
→ electronic pH tester – 0.0-14.0 pH
→ Sulfite (as Na2SO3) – 0.0-20.0 mg/L (ppm) | 0-200 mg/L (ppm)
Water Quality Test Kit – Accurate and Reliable Water Quality TestsNew
COMPANY: HANNA ROMANIA
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/816 | HI3817 | WATER QUALITY TEST KIT COMPLETE |
The Hanna HI3817 combination test kit offers all the necessary equipment for accurate and reliable water quality testing.
→ Alkalinity (as CaCO3) – 0-100 mg/L (ppm) | 0-300 mg/L (ppm)
→ Chloride – 0-100 mg/L (ppm) | 0-1000 mg/L (ppm)
→ Hardness (as CaCO3) – 0.0-30.0 mg/L (ppm) | 0-300 mg/L (ppm)
→ Iron – 0-5 mg/L (ppm)
→ electronic pH tester – 0.0-14.0 pH
→ Sulfite (as Na2SO3) – 0.0-20.0 mg/L (ppm) | 0-200 mg/L (ppm)
Professional Waterproof Portable pH/ORP/ISE Meter – HI98191New
COMPANY: HANNA ROMANIA
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/133 | HI98191 | WATERPROOF PORTABLE PH/ORP/ISE METER WITH GLASS ELECTRODE
AND CALIBRATION SOLUTION, CALIBRATION CHECK RANGE -2.0 TO 20.0 PH,TEMPERATURE -20.0 TO 120.0 DC/-4.0 TO 248.0 DF |
The HI98191 is a rugged, portable pH/ORP/ISE meter with the performance and features of a benchtop meter. This professional, waterproof meter complies with IP67 standards and measures pH, ORP, ISE, and temperature. The HI98191 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable carrying case.
→ CAL Check
→ ISE in Choice of Concentration Units
→ Ergonomic, One-Handed Operation
→ Ergonomic, rugged, waterproof (IP67) design
→ Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.
→ Displays overall probe condition based on offset and slope after calibration
PH-80: pH HydroTester SeriesNew
COMPANY: HM DIGITAL INC USA
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/814 | HM PH80 | WATER RESISTANT ECONOMY PH AND TEMPERATURE METER LARGE
LCD DISPLAY AUTOMATIC TEMPERATURE COMPENSATION (ATC) INCLUDES A TRANSLUCENT CAP, BATTERIES, STORAGE SOLUTION AND PH 7.0 BUFFER (POWDER) |
The PH-80 has proven to be the MOST reliable pH meter in its price range. It has become a favorite in such applications as hydroponics & gardening, pools & spas, aquariums & reef tanks, water ionizers, drinking water and more.
→ pH Range: 0 – 14
→ Temperature Range: 1-55 °C; 32-130 °F
→ Resolution: 0.1 pH; Temperature resolution is 0.1 °C/F
→ Accuracy: +/- 0.2 pH; Temperature accuracy is +/-2%
→ Calibration: Digital automatic calibration (one point)
→ Minimum EC/TDS: 10 µS/5 ppm
→ Electrode: Glass sensor and reference tube electrodes
→ Power source: 3 x 1.5V button cell batteries (model LR44 or equivalent; included)
→ Dimensions: 15.3 x 3.2 x 1.8 cm (6.0 x 1.3 x 0.7 inches)
→ Weight: 53.9 g (1.9 oz)
Multiparameter Waterproof MetersNew
COMPANY : HANNA ITALY
SOM CODE | Model | Description | Images | Catalogue |
---|---|---|---|---|
1462/980New | HI98194 | MULTIPARAMETER PORTABLE WATERPROOF WITH
HI7698194 PROBE,HI7698194-1,HI7698194-3,HI769 8194 PH/ORP/EC/DO SENSOR,HI76981942 PROBE MAINTENANCE KIT,HI7042S,HI9298194 HANNA PC SOFTWARE |
![]() |
![]() |
1462/981 | HI9829-03042 | MULTI PARAMETER PH/ISE/EC/DO/TURBIDITY
WATERPROOF METER,4 METER PROBE CARRYING CASE 230 V/60Hz |
![]() |
![]() |
1462/983 | HI7609829-10 | ROMANIA AMMONIUM ION SELECTIVE ELECTRODE
FOR HI9829 MULTIPARMETER PORTABLE METER |
![]() |
![]() |
1462/984 | HI7609829-11 | CHLORIDE ION SELECTIVE ELECTRODE FOR HI9829
MULTIPARMETER PORTABLE METER |
![]() |
![]() |
1462/986 | HI7609829-12 | NITRATE ION SELECTIVE ELECTRODE FOR HI9829
MULTIPARMETER PORTABLE METER |
![]() |
![]() |
1462/987 | HI9829-10/11 | 10 PPM AND 100 PPM AMMONIUM CALIBRATION
STANDARD SACHETS FOR HI9829 |
![]() |
|
1462/988 | HI9829-12/13 | ISE STANDARD KIT FOR HI7609829-11-CHLORIDE ISE | ![]() |
|
1462/989 | HI9829-14/15 | ISE STANDARD KIT FOR HI 7609829-12-NITRATE ISU | ![]() |
EDGE Single Parameter Meters
COMPANY : HANNA ITALY
SOM CODE | MODEL | DESCRIPTION | CATALOGUE | YOUTUBE |
---|---|---|---|---|
1462/135 | HI2002-02 | EDGE PH/ORP METER WITH CAP
CHECK,MULTIPLE CALIBRATION POINTS, BUILT- IN TEMPERATURE SENSORON ALL ELECTRODES,LARGE, EASY TO READ LCD,CAPACITIVE TOUCH, DUAL USB PORTS, RECHARGEABLE BATTERY |
edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. edge is a single meter that can measure pH and ORP and is incredibly easy to use.
→ pH Range : -2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode)
→ pH Resolution : 0.001 pH, 0.01 pH
→ pH Accuracy (@25ºC/77ºF) : ±0.01 pH, ±0.002 pH
→ pH Calibration : 5 points (Standard mode)
→ pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*
→ mV Range : ±1000.0 mV; ±2000.0 mV
→ mV Resolution : 0.1 mV
→ mV Accuracy : ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
→ Relative mV : Calibration Single point calibration
PH BENCH METER
COMPANY : HANNA ITALY
SOM CODE | Model | Description | Range(pH) | Resolution(pH) | Accuracy(pH) | Catalogue | Image |
---|---|---|---|---|---|---|---|
1462/254New | HI5522-02 | PH/MV/ISE AND EC/TDS/SALINITY/RESISTIVITY METER | -2.000 to
20.000 pH |
0.1, 0.01, 0.001 pH | ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD | ![]() |
![]() |
1462/253 | HI4222-02 | pH-Meter pH/mV/ISE/Conductivity/ Resistivity/Salinity TDS/°C/Calibration |
-2,0 … 20,0 /
-2,00 … 20,00 / -2,000 … 20,000 pH |
0,1/0,01/0,001 pH | ± 0,1 / ± 0,01 / ± 0,002 PH | ![]() |
![]() |
1462/212 | HI 2211-02 | Basic Benchtop Meter (pH/mV/°C) |
-2.00 to 16.00 | 0.01 | ±0.01 | ![]() |
![]() |
1462/256 | HI 255 | 6 in 1 Bench Meter (pH/ORP/EC/TDS/NaCl/°C) |
-2.000 to
16.000 / ±699.9 mV; |
0.01 | ±0.01; ±0.002 / ±0.2 mV | ![]() |
![]() |
1462/56 | HI 112 | High Precision pH Meters (pH/°C) |
-2.00 to 16.00; -2.000 to16.000 |
0.01 pH; 0.001 pH |
±0.01 pH; ±0.002 pH |
![]() |
![]() |
1462/57 | HI 4211 | Graphic Design pH Meter (pH/mV/°C) |
-2.000 to
20.000 |
0.1, 0.01, 0.001 | ±0.1,±0.01,±0.002 ±1 LSD | ![]() |
![]() |
1462/221 | HI 221 | Calibration Check pH Meters (pH/mV/°C) |
-2.00 to 16.00 | ±0.01 | 0.01 | ![]() |
![]() |
1462/250 | HI 4521 | pH & Conductivity bench meter (pH/mV/Conductivity/Resistivity TDS/Salinity/°C) |
-2.0 to 20.0; -2.00 to 20.00; -2.000 to20.000 |
0.1;0.01;0.001 | ±0.1;±0.01;±0.002 | ![]() |
![]() |
1462/301 | pH 301 | pH Bench Meter (pH/mV/°C/ppm) |
-1.999 to
19.999 |
0.01; 0.001 | ±0.002 | ![]() |
![]() |
1462/302 | pH 302 + HI76405 |
pH Bench Meter (pH/mV/°C/ppm) |
0.00 to 14.00 | ±0.01 | 0.01 | ![]() |
![]() |
1462/211 | pH 211 | pH/mV Bench Meter (pH/mV/°C) |
0.00 to 14.00 | ±0.01 | 0.01 | ![]() |
![]() |
1462/209 | pH 209 | pH/mV Bench Meter (pH/mV/°C) |
0.00 to 14.00 | ±0.01 | 0.01 | ![]() |
![]() |
1462/251 | HI 121 | Professional Meters (pH/mV/Selediw Ions/°C) |
-2.00 to 16.00 -2.000 to16.000 |
0.01 | ±0.01 | ![]() |
![]() |
CLEAN PH500 pH / mV Meter
COMPANY : CLEAN INSTRUMENTS CHINA
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1458/64 | PH500 | TEMP PH METER,RANGE -2.00 +16.00 PH -2000 +2000 MV-
5.0+120.0°C /23.0-248.0°F,CALIBRATION POINT UP TO 5(AUTO RECOGNIZED), MEMORY 100 SETS, DIMENSIONS 150*194*56MM (W*L*H), AUTO POWER OFF 10 MINUTES WITHOUT KEY BE PRESSED, ADAPTER AC100-240V |
Features
→ Easy-to-read LCD Display with high luminant backlight
→ Up to 3 points auto-buffer-recognition: Zero offset, Slope of Acid/Alkali segment, Ensure accurate measuring results for the full range with Calibrated pointed displayed
→ One key to check through all the settings, including: Zero offset, Slope of Acid/Alkali segment, and all the settings
→ 150 data sets memory stores and recalls
→ Auto Power off saves battery after 10-mins non-use
→ Detachable Electrode Stand organizes multiple electrodes neatly, easy installing at either left or right side and holds them firmly in place
pH/mV/DC Meter
COMPANY : HANNA ITALY
SOM CODE | Model | Description | Range(pH) | Resolution(pH) | Accuracy(pH) | Catalogue | Image |
---|---|---|---|---|---|---|---|
1462/300 | PH300 | PH/MV/DC METER W/ELECTRODE COMBINATION BNC &ELECTRODE HOLDER. | ![]() |
||||
1462/982 | HI 9828 | Multiparameter Water Quality
Meter |
0.00 to 14.00 | 0.01 | ±0.01 | ![]() |
![]() |
1462/521 | HI 99161 | pH Meter for Food & Dairy (pH/°C) |
-2.00 to 16.00 | 0.01 | ±0.2 | ![]() |
![]() |
1462/110 | HI 9025C | (pH/ORP/mV/°C) Meter | 0.00 to 14.00 | 0.01 | ±0.01 | ![]() |
![]() |
1462/23 | HI 9210N | Waterproof pH Meter (pH/°C) |
0.00 to 14.0 | 0.01 | ±0.02 | ![]() |
![]() |
1462/31 | HI 991301 | Megameter (pH/EC/TDS/°C) | 0.00 to 14.00 | 0.01 | ±0.01 | ![]() |
![]() |
1462/32 | HI 991300 | Waterproof Meter (pH/EC/TDS/°C) |
0.00 to 14.00 | 0.01 | ±0.01 | ![]() |
![]() |
1462/1 | HI 8014 | Meter witd electrode (pH/mV/DC) |
0.00 to 14.00 | 0.01 | ±0.01 | ![]() |
![]() |
1462/34 | HI 9812-0 | Versatile Instruments (pH/EC/TDS/°C) |
0.0 to 14.0 | 0.1 | ±0.01 | ![]() |
![]() |
1462/813 | HI 9813-6 | GroChek Meter (pH/EC/TDS/°C) |
0.0 to 14.0 | 0.1 | ±0.1 | ![]() |
![]() |
1462/255 | HI 931001 | Electrode Simulator with Display (pH/mV) |
0.00 to 14.00 | 0.0 | ±0.1 | ![]() |
![]() |
1462/55 | HI 8424 | Automatic calibration meter (pH/mV/°C) |
-2.00 to 16.00; | 0.01 | ±0.01 | ![]() |
![]() |
1462/812 | HI9811-5 | Portable meters (pH/EC/TDS/°C) |
0.0 to 14.0 | 0.1 | ±0.01 | ![]() |
![]() |
1462/317 | 1462/33 | HI 99163 | pH Meter (pH/°C) | ·2.00 to 16.00 | 0.01 | ±0.02 | ![]() |
![]() |
1462/315 | HI 8314 | Portable meter (pH/mV/°C) |
0.00 to 14.00 | 0.01 | ±0.01 | ![]() |
![]() |
1462/136 | HI 98150 | Waterproof(pH/ORP/C) meter with intelligent electrode |
-4.0 to 20.0 pH; -4.00 to 20.00pH |
0.1; 0.01 | ±0.1; ±0.01 pH | ![]() |
![]() |
1462/131 | HI 9124 | Waterproof(pH/mv/°C)meter | -2.00 to 16.00 | 0.01 | ±0.01 | ![]() |
![]() |
pHep+ Waterproof Pocket pH Tester with 0.01 pH Resolution – HI98108New
COMPANY : HANNA ITALY
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/200 | HI98108 | POCKET PHEP+ PH 0.01 TESTER AND DC WITH ATC WATERPROOF |
The HI98108 pHep+® pH tester provides high accuracy measurements in a rugged pocket-sized design. This meter features an exposed temperature sensor that will provide rapid automatic temperature compensated measurements. The simple two-button operation provides one button for ON/OFF, the other for calibration. Being lightweight and only 0.7″ thick, the pHep+ is extremely ergonomic and fits comfortably in your hand.
→ pH Range : 0.00 to 14.00 pH
→ pH Resolution : 0.01 pH
→ pH Accuracy : ±0.10 pH
→ Temperature Range : 0.0 to 50.0 oC (32.0 to 122.0 oF)
→ Temperature Resolution : 0.1 oC / 0.1 oF
→ Temperature Accuracy : ±0.5 oC / ±1.0 oF
Platinum ORP Half-Cell Electrode with BNC Connector – HI3133B
COMPANY: HANNA ROMANIA
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/222 | HI3133B | PLATINUM ELECTRODE WITH BNC CONNECTOR |
The HI3133B is a glass body ORP half-cell electrode with a BNC connector. This sensing electrode is made with a platinum pin and is to be used in conjunction with a reference half-cell electrode. This design consideration is ideal for use in ORP titrations as well as for general purpose measurements.
→ Half-Cell Design
→ BNC Connection
→ Platinum Sensing Pin
→ Glass Body
→ BNC Connector
→ ORP Sensing Type Platinum
→ Body Material glass
→ Tip / Shape platinum pin
→ Temperature Operating Range -5 to 100°C (23 to 212°F)
→ Body Length/Overall Length 120 mm / 163.5 mm
→ Outer Diameter 12 mm
→ Cable coaxial
→ Connector Type BNC
→ Recommended Use general purpose, potentiometric titration
pH Tester / pH Electrode
COMPANY : HANNA ITALY
SOM CODE | Model | Description | Range(pH) | Resolution(pH) | Accuracy(pH) | Catalogue | Image |
---|---|---|---|---|---|---|---|
1462/129 | HI 98129 | waterproof testers (pH/EC/TDS/°C) |
0.00 to 14.00
pH |
0.01 | ±0.05 | ![]() |
![]() |
1462/127 | HI 98130 | Combo tester (pH/EC/TDS/°C) |
0.00 to 14.00
pH |
0.01 | ±0.05 | ![]() |
![]() |
1462/128 | HI 98128 (pHep5) |
Wlllerproo Testers (pH/°C) |
-2.00 to 16.00 | 0.01 | ±0.05 | ![]() |
![]() |
1462/2 | HI98107 | Electronic Tester(pH) | 0.0 to 14.0 | 0.1 | ±0.1 | ![]() |
![]() |
1462/114 | HI 98114 (Watercheck) |
One Stick Meter (pH/~S/cm) |
0.0 to 14.0 | 0.1 | ±0.2 | ![]() |
![]() |
1462/115 | HI 98115 (Watercheck1) |
pH Meter (pH/~S/cm/ppm) | 0.0 to 14.0 | 0.1 | ±0.2 | ![]() |
![]() |
1462/14 | HI 98151 (pHep”‘1) |
Microprocessor (pH) Testers | 0.0 to 14.0 | 0.1 | ±0.1 | ![]() |
![]() |
1462/17 | HI 98153 (pHep”‘3) |
![]() |
![]() |
||||
1462/15 | HI 98103 (Checker 1) |
Litmus Paper Meter (pH) |
0.00 to 14.00 | 0.01 | ±0.2 | ![]() |
![]() |
1462/12 | PICCOLO+ | pH Meter with Electrode (pH/°C) |
1.00 to 13.00
pH |
0.01 pH/0.1°C | ±0.01 pH/±1 °C | ![]() |
![]() |
BENCHTOP pH METER
COMPANY : VWR,U.S.A.
Specification:
SOM CODE | D1254/27 | D550/18 |
---|---|---|
MODEL | 10010-450 | 11388-340 |
PH Range | –2.000 to 19.999 | |
Resolution | 0.1/0.01/0.001 | |
Relative accuracy | ±0.002 | |
Mv Range | ±1999.9 | |
Resolution | 0.1 | |
Relative accuracy | ±0.2 or 0.05%, whichever is greater | |
Temp Range | –5 to 105°C (23 to 221°F) | |
Resolution | 0.1 up to 99.9°C | |
Relative accuracy | ±0.1°C | |
Catalogue | ||
Images | ![]() |
![]() |
Jenway 3520 pH/mV/Temperature Meter
COMPANY : JENWAY ENGLAND
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1458/69 | 3520 | PH/MV/TEMP METER BENCH TOP W.PH ELECTRODE,BNC
PLUG4,7,10 BUFFER SACHETS230V |
→ 3 decimal place pH resolution
→ 3 point pH calibration
→ Choice of pH calibration buffer types
→ Differential pH input
→ Security code protected user data
→ Calibration data status display
→ Calibration reminder
→ 500 reading memory
→ Comprehensive data logging options
→ RS232 serial interface and IrDA printer interface
→ Alarm outputs (open collector and audible)
→ Analogue recorder output
→ Wall mounting option
→ Back lit 1/8 VGA monochrome liquid crystal display
→ Multi-language operation
SOM CODE : 1462/6
MODEL : 3080/3080HL, 3090/3090HL
COMPANY : JENWAY, ENGLAND.
pH METER
The industrial range of electrochemical instrument are supplied in either DIN standard sized steel panel mounting cases. Or wall mounted water resistant cases.
All of these units will measure pH over the range of 0 to 14pH with a switchable resolution of 0.1pH to 0.01pH.
The pH mode is automatically temperature compensated over the range of 0 to 1000C. A millivolt mode is also provided for the measurement of Redox potentials.
Specifications :
Ranges | 0 to 14.0 pH | 0 to 14.00 pH | 0 to + 1999 mV |
---|---|
Resolution | 0.1pH | 0.01pH | 1 mV |
Accuracy | + 0.1 pH | + 0.2 pH | + 1mV |
Display | 12.5 mm LED |
Power | 110/240V AC, 50/60Hz. |
Size/Weight | 3080 — 96x96x150mm /1.1 kg 3090 — 225x220x125mm / 2 kg |
SOM CODE : D150/558
Model : KH-58600-00
COMPANY : COLEPARMER,U.S.A
→ Use this compact meter as a handheld or benchtop unit—front cover folds down to form a stand for benchtop use
→ Error messages alert you to incorrect calibration procedures or faulty electrode
→ Use recorder output to make copies of pH, mV, and temperature readings
Easy-to-use meter provides the basic features you would expect with some added enhancements. Meter offers manual or automatic temperature compensation, dual display of pH/temperature or mV/temperature, and portable design with a long battery life. Calibrates quickly with up to two-point calibration and automatic buffer recognition. Diagnostic messages guide you through use, and the recorder output provides for easy data documentation.
pH CONTROLLER
COMPANY : HANNA, ITALY
SOM CODE | 1462/872 | 1462/93 | 1462/871 |
---|---|---|---|
MODEL | HI 8720E | HI931700 + HI1002/3 | HI 8711E 020 |
Description | ORP CONTROLLER WITH SELF
DIAGNOSTIC TEST WITH PH ELECTRODE |
MINI PANEL MOUNTED pH
CONTROLLER |
pH Controllers DUAL OUTPUT
pH 0-20 MA |
Range (pH) | -1000 to +1000 mV | 0.00 to 14.00 | |
Resolution (pH) | 1 mV | 0.01 | |
Accuracy (pH) | ±5 | ±0.02 | |
Calibration | slope: 90 to 110% witd trimmer | Offset: ±2 pH by trimmer 1 Slope:
80 to 110% by slope trimmer |
|
Catalogue | |||
Images | ![]() |
![]() |
![]() |
COMPANY : HANNA ROMANIA
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
1462/132 | HI 1285-5 | PH/EC/TDS ELECTRODE FOR GREENHOUSES HYDROPONICS
ENVIRONMENTAL MONITORING WATER TREATMENT BOILERS WITH MULTI PIN CONNECTOR RECOMMENDED FOR HI9811-5,HI9812-5.HI9813-5 SERIES |
→ Body Material : polypropylene
→ Reference : single, Ag/AgCl
→ Junction / Flow Rate : cloth
→ Electrolyte : gel
→ Range pH : 0 to 13, EC
→ Max Pressure : 0.1 bar
→ Tip Shape : spheric (8 mm)
→ Diameter : 16 mm
→ Body Length / Overall Length : 95 mm / 185 mm
→ Recommended Operating Temperature : 0 to 50°C (32 to 122°F) – LT
→ Temperature Sensor : yes
→ Matching Pin : no
→ Amplifier : yes
→ Digital : no
→ Cable : 7-pole; 1 m (3.3′)
→ Connection : DIN
→ Applications : boilers, cooling towers, environmental monitoring, greenhouses, hydroponics, water treatment
SOM CODE : 1462/144
MODEL : HI1144B
COMPANY : HANNA ROMANIA
STANDARD CALOMEL ELECTRODE REFERENCE SINGLE, HG/HG2CL2,JUNCTION/FLOW RATE CERAMIC, SINGLE /15-20 µL/H,ELECTROLYTE KCL 3.5M,MAX PRESSURE 0.1 BAR,RANGE PH: 0 TO 14,RECOMMENDED OPERATING TEMP.20 TO 40°C (68 TO 104°F),TIP/SHAPE SPHERIC (DIA: 9.5 MM)
Junction/Flow Rate : ceramic, single / 15-20 µL/h
Electrolyte : KCl 3.5M
Max Pressure : 0.1 bar
Range : pH: 0 to 14
pH Electrodes
COMPANY : HANNA ITALY
SOM CODE | 1462/332 | 1462/124 | 1462/121 | 1462/123 | 1462/126 | 1462/54 | 1462/120 | 1462/53 |
---|---|---|---|---|---|---|---|---|
MODEL | HI 1332B | HI 1131B | HI 1131P | HI 1230B | HI 5412 | HI 3131B | HI 1139B | HI1053B |
Description | pH
Electrode and Field BNC Connection |
Refillable, Combination
pH Electrode |
Refillable, Combination
pH Electrode |
Combination
pH Electrode |
Reference
Electrode for ISE and Titrations |
Refillable
Combination ORP Electrode |
pH
Electrode for pH 211 |
pH Electrode
Combination BNC Emulsion |
Flow Rate | ceramic, single / 15-20 µL/h | ceramic, single | ceramic, single / 15-20
µL/h |
|||||
Electrolyte | KCl 3.5M | KCl 3.5M | KCl 3.5M + AgCl | Gel | KCl 3.5M | KCl 3.5M + AgCl | ||
Range(pH) | 0-13 | 0-13 | 0-13 | 0-13 | ||||
Images | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
SOM CODE : 1462/242New
MODEL : HI 76310
COMPANY : HANNA ITALY
PLATINUM 4 RING CONDUCTIVITY TDS PROBE WITH 1 METER 3.3 FEET CABLE
4-ring interchangeable platinum probe with built-in temperature sensor, ATC and 1 m (3.3′) cable, for use with HI 3512, HI 2300 and HI 2550.
The potentiometric method eliminates polarization and thus is the most accurate way to measure electrical conductivity in liquids. The probe can also measure in a wider conductivity range because it does not suffer from electrolysis. Models with stainless steel and platinum rings are available. The platinum probes are ideal for high temperature applications, are easier to clean and provide more stable readings.
General Purpose Glass Bodied pH Electrode
COMPANY : JENWAY,ENGLAND
This electrode is designed for standard measurements of general solutions. It is designed for general purpose pH measurement for accurate Q.C. and research work.
SOM CODE | MODEL | DESCRIPTION | CATALOGUE |
---|---|---|---|
D71 & 1522/7 | 924005/3030 | PH ELECTRODE GLASS COMBINATION |
FLUORIDES STANDARD / TISAB SOLUTION(FLURIDES STANDARD SOLUTION) / CALIBRATION KIT
COMPANY : HANNA, ITALY
SOM CODE | MODEL | DESCRIPTION | IMAGES |
---|---|---|---|
N84/15 | HI7061L | CLEANING SOLUTION FOR GENERAL PURPOSE. 500ML BOTTLE | ![]() |
N84/32 | HI70032P | 1382 MG/L (PPM) TDS VALUE AT 25 DEGREE CELCIUS 20 ML
SACHETS.25 PCS PER PACK |
![]() |
N84/35 | HI70030P | 12880 US/CM EC VALUE AT 25 DEGREE CELCIUS.20ML
SACHETS(25PCS/PACK) |
![]() |
1462/410 | HI4010-02 | Fluoride Standard 100ppm,500ml | ![]() |
1462/402 | HI4010-10 | Fluoride Standard 10ppm with TISAB II 500ml | ![]() |
1462/400 | HI4010-11 | Fluoride Standard 1ppm with TISAB II 500ml | ![]() |
1462/405 | HI7023/1L | TISAB Solution 500ml | ![]() |
1462/403 | HI7023/1L | TISAB KIT(Solution)(Fluoride Standard Solution) | ![]() |
1462/216 | HI70702/1L | Calibration Kit With Fluoride Solutions 1 L. | ![]() |
1462/217 | HI70703/1L | Calibration Kit With Fluoride Solutions 1 L | ![]() |
D315/2 | HI 70004P | pH 4.01 Calibration Solution, 25 x 20mL, case of 25 | ![]() |
1462/409 | HI 7082 | Electrolyte Solution, 3.5M KCl 4 x 30 mL bottle | ![]() |
N84/14 | HI70300L | Storage Solution For pH/ORP Electrode 460 ml/Bottle | ![]() |
1462/151 | HI 7071 | Electrolyte Solution, 3.5M KCl + AgCl 4 x 30 mL bottles | ![]() |
D315/3 | HI 70007P | pH 7.01 Calibration Solution, 25 x 20mL, case of 25 | ![]() |
SOM CODE : D179/37
MODEL : HI38061
COMPANY : HANNA ITALY
COMPLETE KIT CASE FOR 38061
Phosphate test kit for irrigation water
The reaction between phosphate and the reagent causes a blue tint in the sample; adaptation of the ascorbic acid method.
Phosphates are widely introduced into the environment from such sources as agricultural fertilisers, cleaning and laundering products, boiler water conditioners and drinking water treatment aids. At high levels, phosphates stimulate the growth of photosynthetic organisms which may contribute to eutrophication of lakes, rivers and ponds. This makes it important to monitor and control phosphate discharges into the environment.
GENRAL PRODUCTS
COMPANY : HANNA ITALY
SOM CODE | MODEL | DESCRIPTION | IMAGES |
---|---|---|---|
1462/130 | HI2003-02 | EDGE DEDICATED EC 230V | |
1462/226 | HI 1288 | Replacement pH/EC/TDS/T Probe HI1288 (HI 1288) | ![]() |
1462/704 | HI 731313 | Maintenance kit for HI 93703 | ![]() |
1462/404 | HI 76404 | Electrode Holder | ![]() |
1462/309 | HI 76405 | Electrode holder witd steel base | ![]() |
1462/122 | HI7669/2N | TEMPERATURE PROBE FOR pH METER | ![]() |
1462/767 | HI766E1 | PROBE FOR GENERAL PURPOSE | ![]() |
1462/86 | HI7686 | CONDUCTIVITY PROBE | ![]() |
Ph Meter / Electrodes / Accessories
COMPANY : CORNING USA
SOM CODE | MODEL | DESCRIPTION | IMAGES |
---|---|---|---|
1462/240 | M240 | PH METER M240 WITH ELECTRODES 240 VOLT (ROW). | ![]() |
1462/106 | M106 | PH METER. | |
1460 | 5 | PH/MV METER 115V 50/60HZ. | |
1462/320 | 475816 | PH METER DELTA M320 W/ INLAB 405 ELECTRODE & CABLE | |
1462/105 | M105 4753820 1P | PH METER HANDHELD M105 ROW VERSION W/ ELECTRODES. | |
1462/107 | 475801 | PH METER POCKET TYPE M107. | |
1462/164 | 51300164 | PROBE ATC FOR PH METER M320. | |
1464 | 0301 OOF | PH METER LIQ CRISTAL DISP PORTABLE. | |
1465 | 47537401 P | PH METER W.ELECT M145 DELTA (AV) 220V/60HZ. | |
1470 | 00311616 P | PH ELECTRODE REFERENCE SERIES 500. | |
1471 | 00311126 F | PH GLASS ELECTRODES 500. | |
1471/1 | 0031120 N | PH ELECTRODE STD GLASS COMBIN. | |
1472 | 00307009 M | PH ELECTRODE LEAD-2MM PIN (PHONETIP). | |
1472/1 | 00307012 E | PH ELECTRODE LEAD-2MM PIN STD. | |
1473 | 00307002 X | PH ELECTRODE LEAD-2MM PIN (PHONETIP). | |
1474 | 477378 | PH ELECTRODE REFERENCE MEMBRANE KIT. | |
1475 | 47610900 K | PH ELECTRODE REFERENCE W/ CERAMIC JUNC. | |
1476 | 47602200 A | PH ELECTRODE REFERENCE W/ TRI PURP GLASSMEMB | |
1477 | 476094 | ELECTRODE ASSEMBLY P.O.2. | |
1478 | 476093 | ELECTRODE ASSEMBLY PCO.2 | |
1480 | 00311207 H | PH COMBINATION ELECTRODE SERIES 500 RUGGED COMBO. | |
1481 | 476117 | PH ELECTRODE ASSEMBLY KIT. |
SOM CODE | Model | Company | Description |
---|---|---|---|
D315/5 | HI7669AW | HANNA ITALY | TEMPERATURE PROBE DOE FOR PH METER. |
D315/4 | HI70010P | HANNA ITALY | CALIBRATION SOLUTION POWDER PH 10.01 AT 25DC 20ML SACHET 25PCS/PKT. |
D315/1 | HI1053B | HANNA ITALY | PH COMBINATION ELECTRODE BNC EMULSIONS. |
D125/15 | 211 | HANNA ITALY | BENCH METER PH- METER |
1462/435 | HI943500C | HANNA ITALY | CONDUCTIVITY ANALOG CONTROLLER WITH DIRECT INPUT FROM POTENTIOMETRIC PROBE |
1462/314 | HI8314 | HANNA ITALY | PH/MV/DC METER W/ ELECTRODE ATC 0.00 TO 14.00 pH. |
1462/310 | HI1310S | HANNA ITALY | PH ELECTRODE GLASS COMBINATION SCREW TYPE. |
1462/204 | HI98230 | HANNA ITALY | PH/ORP/DC METER , PRINTING + LOGGING WITH GLP |
D406/4 | 924007 | JENWAY ENGLAND | DEMI MICRO 4.5MM DUA (90MM REACH) GLASS PH ELECTRODE (FOR MODEL 3020). |
D406/3 | 924005 | JENWAY ENGLAND | GENERAL PURPOSE GLASS PH ELECTRODE (SUITABLE FOR MODEL 3020) |
1458/4 | PCP201 | JENWAY ENGLAND | PH ELECTRODE COMBINATION. |
1458/61 | 3070/P | JENWAY ENGLAND | PH/MV/DC METER W/ PCP501 COM ELEC PCT101 ATC PH4. |
D128/168 | PCEPH000002 | IWT ITALY | PH ELECTRODE CONTROLLER+ GLAND MATERIALE PLASTIC |
D96/4 | 09 876 17 | FISHER/SMS U.S.A | PH 0-14 BY 16 X 80MM 100/PKT. |
1462/159 | 51300159 | CORNING ENGLAND | PROBE ATC FOR PH METER M240. |
1469 | 00311214 F | CORNING ENGLAND | PH ELECTRODE GEL FILL POLY-PROT COMBO. |
1460 | 5 | CORNING ENGLAND | PH/MV METER 115V 50/60HZ. |
D110/3 | DD59002-02 | COLEPARMER U.S.A | METER PH/MV/TEMP W/ ELECTRODE. |
D255/3 | 35624-00 | COLEPARMER U.S.A | PH METER HAND HELD TYPE. |
D365 | 05990-10 | COLEPARMER U.S.A | PH ELECTRODE GLASS BODY COMBINATION HALF-CELL. |
D128 | 9307 | BAMO FRANCE. | PH ELECTRODE 0-14 PH/0-90DC CODE:150 100. |
SP300/12 | MN009-1 | AIRSEP U.S.A | MANUAL POUCH LT GRAY SUEDE PSA BACK 9X6INCH NEWL. |
1462/734 | HI97734 | HANNA ROMANIA | FREE & TOTAL CHLORINE HIGH RANGE PORTABLE PHOTOMETER, RANGE 0.00 TO 10.00 MG/L (AS CL2) ,CHLORINE RESOLUTION 0.01 MG/L, ACCURACY ±0.03 MG/L ±3% OF READING,LIGHT SOURCE LED AT 525 NM,1.5V AA BATTERY |
1462/257 | HI92000 | LABORATORY SCICHEM, UK | COMPATIBLE SOFTWARE FOR LOGGING INSTRUMENTS PHOTOMETERS AND
TURBIDITY METERS FOR WINDOWS |
D441 | 027017 | BIBBY SCIE | ATC PROBE FOR JENWAY PH METER MODEL 3030 |
1462/158 | HI 710006 | HANNA ROMANIA | POWER ADAPTER, 230 VAC TO 12 VDC, EUROPEAN PLUG |
1458/60 | 3030/P | JENWAY ENGLAND | PH/MV/C MICROPROCESSOR METER COMPLETE |
1491 | P514K & W03J | CONSORT BELGIUM | PH METER KIT LABORATORY & PT100 TEM COMPENSATOR |
1489/1 | 01.00.965 | GIBERTINI ITALY | PH ELECTRODE COMBINED MONOTUBE W/ CABLE |
1456 | 33-3031-000 | KENT | TEMPARATURE COMPENSATOR FOR130B,30C,38-A & E |
1452 | DP 100 | GIBERTINI ITALY | PH SOLUTION KIT (BUFFER) |
1451 | DP 100 | GIBERTINI ITALY | PH/MV METER DIGITAL 220V |
1450 | DP 10 | GIBERTINI ITALY | PH/MV METER DIGITAL 220V |
1455 | 11-3030-000 | KENT | PH METER EIL PORTABLE |
1453 | WQC-1A | TOAELE | WATER QUALITY CHECKER W/ STD ACCESS |
Note : Please mention the product “SOM CODE” while making request for quotation and send it to *****@somatco.com