Turbidity (EPA) Portable Meter – HI98703
COMPANY: HANNA ROMANIA

SOM CODE MODEL DESCRIPTION CATALOGUE
1462/702 HI98703-02 TURBIDITY METER WITH FAST TRACKER TECHNOLOGY (EPA)

RANGE 0.00 TO 9.99 10.0 TO 99.9 AND 100 TO 1000 NTU

230V/60HZ

The HI98703 is a high accuracy (±2% of reading plus 0.02 NTU) Turbidity Portable Meter. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI98703 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.

→ Fast Tracker™ – Tag Identification System (T.I.S)
→ USB for data transfer
→ Operates on batteries or line voltage
→ EPA Compliant
→ High accuracy at low ranges (below 0.05 NTU)
→ GLP Features
→ One, two or three-point calibration
→ Log up to 200 Records

BENCHTOP TYPE TURBIDITYMETER
COMPANY : HANNA, ITALY

SOM CODE 1462/2000 1462/702 1081/223
MODEL LP2000 HI98703 HI88703-02
Description Turbidity Meter Sophisticated Bench Type Turbidity Meter Sophisticated Bench Type Precision Turbidity Benchtop meter(Ratio / Non-Ratio)
Range 0.00 to 50.00 FTU 0.00 to 9.99; 0.00 to 9.99;
Resolution 0.01/1 FTU 0.01 NTU from 0.00 to 9.99 NTU; 0.01; 0.1 NTU;
Accuracy + 0.5 FTU ±2% of reading plus 0.02 NTU ±2% of reading plus 0.02 NTU
Light Source High Emission Infrared LED Tungsten filament lamp tungsten filament lamp / greater than 100,000 readings
Light Detector Silicon Photocell Silicon Photocell
Catalogue
Images

TURBIDITY METER
COMPANY : VWR, USA.

SOM CODE MODEL DESCRIPTION CATALOGUE
1554/6 66120-200 Turbidity Meter Digital with Case & Transformer

Product description :
Meet your sampling requirements with this affordable turbidity meter which measures the amount of suspended particle in a clear liquid. The meter accurately reads the amount of reflected light at 900 to the incident angle of a light source. The reflected light is proportional to the number of suspended particle in a sample.

This Turbidity meter can be used in the fields by adding the rechargeable, 12V sealed battery which comes with a luggage-type carrying case and permanently sealed calibrating standards of 0 NTU and 10 NTU.

Resolution : 0.01(0-20), 0.1 (0-200)
Accuracy : + 2%
Display : 0.5 in.(1.25 cm) LCD

PORTABLE TURBIDITYMETER
COMPANY : HANNA, ITALY.

HI 93703C microprocessor-based turbidity meter provide lab grade accuracy even in the field. with a few keys and weighing only 350 grams. This is the only only turbidity meter equipped with infrared LED as a light source. The meter’s versatile and durability ensures low maintenance.

Specifications :

SOM CODE MODEL DESCRIPTION CATALOGUE
1462/703 HI 93703C Turbidity Meter With Maintenance Kit
Range 0.00 to 50.00 FTU
Resolution 0.01/1 FTU
Accuracy + 0.5 FTU
Typical EMC Deviation +2 Full Scale
Light Source High Emission Infrared LED
Light Detector Silicon Photocell
Computer Interface RS232
Battery Type/Life 4 x 1.5V AA batteries / 60 hours Auto-shut off after 5 minutes.
Dimension/Weight 220 x 82 x 66 mm / 510g

TURBIDITYMETER
COMPANY : VELP SCIEN ITALY

SOM CODE MODEL DESCRIPTION CATALOGUE
1887/131 R109B12150 TB1 TURBIDIMETER

The TB1 portable turbidimeter allows to measure in a simple and precise way turbidity of an aqueous sample, the measure given is in Nephelometric Turbidity Units (NTU). The light source used is a infrared LED. The high quality, semplicity of use, the total waterproof resistance of the TB1 turbidimeter are characteristics that make it unique and of big interest for the operators working in the water analysis field.

The measure torbidity is according the international analytical method ISO 7027, that allows an high reproducibility of the measured values.

With few buttons it is possible to effect a simple and rapid calibration: in few seconds the instruments gives to the operator the information requested about the standard and the sample to be analyzed.

→ Measurement Method : ISO 7027 compliant nephelometric method (90°)
→ Measurement Range : 0 to 1000 NTU
→ Repeatability : ± 0.01 NTU or ± 1% of reading, whichever is greater with gel samples
→ Light Source : Infrared-emitting diode (850 nm wavelength)

PORTABLE TURMBIDITYMETER
PART NUM : 46500-00
HACH, MADE IN USA.

SOM CODE MODEL DESCRIPTION CATALOGUE
D96/46 2100P The Portable Turbidimeter gives you lab quality results in a portable unit

→ Turbidity range: 0 to 1000 NTU
→ Selectable signal averaging mode compensates for fluctuations in readings caused by movement of large particles in the light path Pre-programmed calibration procedure, with microprocessor-controlled adjustment of calibration curve. No potentiometers to adjust → Electronic zeroing: compensates for electronic and optical offsets. No manual adjustments are required
→ Direct digital readout in NTU
→ Meets or exceeds USEPA method 180.v1 criteria
→ Comes with six sample cells, 4 sealed vials of StablCal Primary Turbidity Standards (< 0.1, 20, 100, and 800 NTU), Secondary Gelex Turbidity Standards, silicone oil and oiling cloth

SOM CODE : 1554/7
MODEL : ISO 702
MADE IN USA.

LAB TURBIDITY METER ISO 7027,230V 60Hz

With the new portable turbidity meters Turb 430 T and Turb 430 IR, the user now has the choice to perform nephelometric measurements at 90° scattered light according to the application and standard required. The Turb 430 IR portable turbidity meter meets the DIN 27027/ISO7027 requirements, the Turb 430 T those of US EPA 180.1. The portable turbidity meter’s measuring range is from 0 to 1100 NTU/FNU and is identified automatically. Accurate measurements by the portable turbidity meters in the lower range, e.g. in drinking water are no problem.

The Turb 430 Portable Turbidity Meters have menu driven 3 point calibration and all measurement functions are easy for even the most inexperienced operator to perform accurate and precise measurements. The calibration is via an AMCO® standards set (0.02-10-1000 NTU). The quality of the measurement results is supported by adjustable calibration intervals with documentation. The Turb 430 Portable Turbidity Meters are not only a field measuring instruments (especially with the practical field case), but also a “small lab instrument” for applications up to 1100 NTU/FNU and with optimum data management. Applications for the portable turbidity meters include all water testing applications, such as drinking water, process control, and the wine making industry.

SOM CODE : P10/21
MODEL : HI 731321
COMPANY : HANNA ITALY

CUVETTE SPARE MEASUREMENT 4PCS/PKT.

Glass cuvettes are constructed of precision glass, necessary for taking accurate measurements with photometers and turbidity meters. Care must be taken when handling. It is important that the cuvette is always clean and without scratches.

For use with HI 83 series photometers, and turbidimeters.

Accessories

SOM CODE Model Company Description
D63/6 8900-011 JOHNBUNN  U.S.A HOUR METER 60HZ.
1081/28 1072-048 JOHNBUNN  U.S.A METER HOUR 60HZ.
D262 6035 JENWAY  ENGLAND TURBIDITY METER W/ CASE & RECHARGEABLE BATT 220V.
D353/2 LM1799 AQUATIC ECO-SYS  U.S.A. LAMOTTE TURBIDITY METER MODEL-2020.
P10/25 HI731325 HANNA ITALY CUVETTE CAP 4PCS/PKT.
1554/8 MADE IN USA SULFAVER 4 PWD. PLWS 100/PK 10ML
1554/9 MADE IN USA LAURYL TRYTOSE BROTD, DHYD 500GM
D96/48 24347-06 MADE IN USA SAMPLE CELL 25 X 60 MM
D96/47 26594-05 MADE IN USA STANDARD CALIBRATION KIT
1156/19 05031-101 MADE IN USA PROB COVER 1000PCS PER BOX IN BOX

Note : Please mention the product “SOM CODE” while making request for quotation and send it to *****@somatco.com