GSR ISOLATED AMPLIFIER
COMPANY : HARVARD ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D341/212 50-9505 For GSR on human subjects for teaching purposes only

The front end of the preamplifier is battery powered (2 x 9 volt transistor radio batteries) while the back end receives its power from the host unit. A meter shows battery state and the batteries are connected only when linked to the host unit. There are 3 ranges (0 to 10 k?, 0 to 100 k? and 0 to 1 M?) and DC level control, built in audio speaker with modulation facility and a normal/differential switch. The maximum sensitivity is 50?/cm of pen deflection when used with the Harvard Apparatus oscillographs. It is supplied with the 50-9521 GSR Finger Electrode Set.

The 50-5966 Isolator Interface is needed to connect this unit to a Universal Oscillograph or Interface Adapter, or it plugs directly into the Harvard Apparatus Student Oscillographs.

COMPANY : HARVARD ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D341/211 50-5966 ISOLATOR INTERFACE UNIT

The sole purpose of this interface is to allow connection of the Harvard Apparatus range of Isolated Preamplifiers to the Universal Oscillograph or Interface Adapter. The On/Off control is used to connect the battery power in the Isolated Preamplifier.

COMPANY : HARVARD ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D101/51 50-9513 UNIVERSAL ISOLATOR
For ECG, EMG, ENG, EOG on human subject for teachpurposes only

The front end of the Preamplifier is battery powered (2 x 9 volt transistor radio batteries) while the back end receives its power from the host unit. A meter shows battery state and the batteries are connected only when linked to the host unit. The input is via either the 3-pin binder socket or the row of five standard color coded 2 mm sockets (labeled LA, RA, LL, RL and C) for 5 electrode ECG measurements. A 7-position ‘limb’ selector allows connection of the standard ECG electrode configurations.

There is a 3-position gain switch (x10, x100 and x1000), an input selector for AC or DC coupled, a filter selector (3 dB down at 30 Hz, 150 Hz and 15 kHz) and a DC level control. Maximum gain when used with a Harvard Apparatus Oscillograph is 30 µV/cm of pen deflection. A comprehensive range of electrodes and input leads is available.

COMPANY : HARVARD ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D101/57 10-1652 IWORK RA EIGHT CHANNEL RECORDER IX-RA-834
D101/58 10-1653 ISOLATED ECG/EMG/EEG/GSR IWIRE RECORDING MODULE

IWIRE-B3G

The iWorx RA Recorder is the most advanced and feature-rich physiological data acquisition system on the market. It comes standard with eight general purpose input channels, a low voltage and high voltage stimulator, eight digital inputs and outputs, a built-in barometric pressure sensor, and four iWire™ inputs.

The iWorx RA exhibits the high resolution, low noise, and flexibility required for a variety of research applications including cardiac function, hemodynamics, isolated tissue and organ studies, exercise physiology research, metabolic function studies, neuroscience and both oocyte and epithelial voltage clamp applications. Incorporating innovative iWire serial interface technology and advanced LabScribe data acquisition and analysis software, the iWorx RA Recorder accommodates a wide range of sensors, transducers, and other devices.

COMPANY : HARVARD, ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
3338/10 50-8150 Student Oscillographs

This versatile, compact, 2-Channel Student Oscillograph is available with curvilinear or rectilinear recording and features. Unlike the Modular Universal Oscillograph, see preceding pages, which supplies power to operate its ampli-fier interfaces, the Student Oscillograph requires freestanding AC or battery operated amplifier

COMPANY : HARVARD, ENGLAND.

These oscillographs are designed around a pen amplifier module which contains the circuits to power the pen and operate the various amplifier interface modules on the following pages. The oscillographs are supplied with 2 or 4 factory-installed pen amplifier modules with either curvilinear or rectilinear writing.

SOM CODE        Model         Description Catalogue
D341/18 &

D350/125

50-8622 OSCILLOGRAPH 2 CHANNEL 230V, ISOMETRIC TRANSDUCER 50CM 50-7905,

TRANSDUCER INTERFACE 50-8861

D314/1 50-8648 OSCILLOGRAPH UNIVERSAL 2 CHANNEL RECTILILINEAR 230V/60HZ.
D350/129 50-8978 Pen Amplifier Module for Curvilinear Oscillograph
330/4 50-9018 Black Ink Cartridge
330/3 50-9034 Paper, 91 m (300 ft) for 2-Channel, Curvilinear Oscillograph
330/5 50-9091 Replacement Pen for Curvilinear Oscillograph
3338/9 50-9372 Paper, 91 m (300 ft) for 4-Channel, Curvilinear Oscillograph
D45/111 50-9315 +

5075

Osillograph 115V+iso.Transducer
D45/111 50-9315 +

5075

Osillograph 115V+iso.Transducer

COMPANY : HARVARD ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D341/93 50-9307 4 CH, OSCILLOGRAPH 230V+

These oscillographs are designed around a pen amplifier module which contains the circuits to power the pen and operate the various amplifier interface modules on the following pages. The oscillographs are supplied with 2 or 4 factory-installed pen amplifier modules with either curvilinear or rectilinear writing.

Curvilinear or rectilinear recording
→ Available in two sizes:
— 2 channels for one or two writing channels
— 4 channels for one, two, three or four writing channels
→ For use with Harvard Apparatus Amplifier Interfaces, which plug in directly to the oscillograph
→ Accept inputs from freestanding amplifiers or transducers via BNC connector (For Harvard Apparatus Research Grade Blood Pressure Transducer, for Isotonic and Isometric Transducers)

COMPANY : HARVARD ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D314/4 50-8861 TRANDUCER INTERFACE FOR MODULAR OSCILLOGRAPH

→ Extremely versatile
→ Two models available:
→ Modular for plugging directly into Modular Universal Oscillographs
→ Freestanding for direct connection to Data Acquisition Systems, Student Oscillograph or other recording devices

The Modular Interface receives its power from the Modular Universal Oscillograph. The Freestanding Interface is AC powered. This interface handles six transducer types using a six-position switch.

Dual Bio Amplifier
COMPANY : HARVARD ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D341/248 77-0248 + 77-

0240

DUAL BIO AMP FE 135 POWERLAB 4/35 AND

LABCHARATPRO

PowerLab 4/35 Data Acquisition System – 4 Channels with LabLabChart Pro Software, Model PL3504/P

→ Full electrical isolation from power-line (mains) circuitry to guarantee subject safety
→ Low-noise, high-gain differential amplifier specifically designed for biological signal measurements
→ Software-controlled low-pass, high-pass and notch filters to remove unwanted signal frequencies for particu-lar uses
→ Audio output for use with EMG signals and similar

COMPANY : HARVARD, ENGLAND

SOM CODE MODEL DESCRIPTION CATALOGUE
D341/1 50-8879 AC/DC Preamplifier Interface
This is a general purpose differential Preamplifier foranimal use only.

→ For ECG, EMG, ENG and EOG.
→ High gain, low noise and drift.
→ Step gain switch, x10, x50, x100, x200, x500, x1000.
→ AC/DC selector switch.
→ DC level control.

There is a 6 position gain switch, an input selector for AC or DC coupled, a filter selector and a DC level control giving a maximum offset range of +4 volts.

Input is via a 7-pin binder socket and output via edge connector into the Universal Oscilloscope or Interface Adapter.

SOM CODE Model Company Description
D75 50-8622 Harvad England OSCILLOGRAPH 2CH 230V W/ STD ACCESSORIES.
D45/13 50 8952 Harvad England BLOOD PRESSURE TRANSDUCER.
D45/12 50 7905 Harvad England ISOMETRIC TRANSDUCER 50GM.
D45/11 50-9315 Harvad England OSCILLOGRAPH UNIVERSAL 4 CHANNEL CURVILINEAR 115V.
D341/4 50-8036 Harvad England ISOMETRIC TRANSDUCER 55GM.
D314/9 50-9984 Harvad England RECORDING SYSTEM 115V W/SPECIAL RECORDING SYSTEM COMPLETE 115V/60 Hz
D314/7 50-3565 Harvad England MYOGRAPH BOARD FOR OSCILLOGRAPH.
D314/8 50-9018 Harvad England CARTRIDGE INK BLACK FOR OSCILLOGRAPH.
D314/3 50-9026 Harvad England PAPER ROLL CHART FOR RECTILINEAR OSCILLOGRAPH.
D314/2 50-9083 Harvad England PEN SPARE FOR RECTILINEAR OSCILLOGRAPH.
D115 50-8861 Harvad England TRANSDUCER INTERFACE.
D115/1 50-8952 Harvad England B.P. TRANSDUCER.
D115/2 50-7905 Harvad England ISOMETRIC TRANSDUCER.
D145/1 50-6360 Harvad England ISOTONIC TRANSDUCER.
330 50-8630 Harvad England OSCILLOGRAPH 2 CH/115V.
D341/210 50-9992 Harvad England RECORDING SYSTEM 230 V
518 XLD-540-A GRIFFIN POWER AMPLIFIER UNIT.
518/1 EKR-650-010M GRIFFIN POWER SUPPLY LOW TENSION VARIABLE VOLT 240V/50HZ.

Note : Please mention the product “SOM CODE” while making request for quotation and send it to *****@somatco.com