1833/53_CB 53

1833/53_CB 53

Incubator

The exact and long-term stable observance of CO2-concentration is of importance for the cell growth requirments.CO2 incubators offer what is currently the highest standard of safety against the most diverse contamination risks.

SOM CODE:1833/53
MODEL :CB 53
COMPANY: BINDER, GERMANY

Description

DESCRPTION

CO2 incubator with additional process controls

The BINDER CB series CO2 incubator is the premium class among the CO2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CO2 incubator of the CB series is up to even complex cultivation experiments or individual environments.

Advantages:
  • Hot air sterilization at 180 °C
  • Seamless, deep-drawn inner chamber made of stainless steel
  • Unique BINDER technology (patented air jacket system, controlled condensation, etc.)
Areas of application:
  • Bio Tissue Engineering
  • In vitro Fertilization (IVF)
  • Clinics / University Hospitals
Features Customer benefits Characteristics
Sterilization
  • Complete elimination of bacteria, spores, etc.
  • Reliable sterilization of the atmosphere and all surfaces
  • Minimal sterilization costs
180 °C hot air sterilization

  • Standards compliance, meets all relevant standards
  • Automatic sterilization process
Permadry™ humidity system
  • Uniform osmotic cell pressure
  • Optimum cell growth even with microwell plates
  • No Provides no sources of contamination.
Controlled humidification system

  • Defined recondensation point
  • Dry interior walls
  • High humidity
  • Rapid humidity recovery times
  • Simple water exchange through water pan
APT.line™ heating technology
  • Optimal, uniform cell growth throughout the inner chamber
Preheating chamber with VENTAIR™ air jacket

  • Homogeneous temperature distribution
  • Rapid recovery after temperature drop
  • Accurate temperature control
Gas distribution
  • Stable pH value
Gas mixing head with venturi effect

  • Homogeneous CO2 distribution
  • Fast effective aeration
Inner chamber concept
  • Easy cleaning
  • Fully usable volume 53, 150, 210 l
  • No Provides no sources of contamination.
Seamless, deep-drawn inner chamber

  • Integrated shelf support system
  • Burr-free stainless steel perforated sheets with tilt protection
CO2 measurement
  • Stable pH value even with frequent door opening
  • Long-term stable system
  • Low maintenance costs
Single-beam infrared sensor

  • Rapid response time
  • Measures CO2 in real-time
  • Independent of gas and humidity
Operating costs
  • Minimal operating costs
  • Time savings
  • Minimal work and material costs for sterilization

Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and best cell growth

  • Temperature range from 7 °C above ambient temperature to 60 °C
  • MCS controller for temperature and CO2 concentration
  • User-friendly LCD screen
    • Easy-to-read menu guide
    • Integrated electronic chart recorder
    • Variety of options for the graphic display of process parameters
    • Real time clock
  • Standard-compliant hot air sterilization at 180 °C (DIN 58947)
  • VENTAIR™ Jacket System
  • Drift-free infrared CO2 measurement system
  • Patended Gas mixing nozzle
  • Permadry System – condensation-free double-pan humidification system, maintains dry interior walls
  • Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges)
  • Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring
  • Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
  • Tightly-fitted inner glass door
  • RS 422 interface for communication software APT-COM™ DataControlSystem
  • 2 perforated stainless steel shelves with standard equipement and O2 control
  • Units are stackable with stacking adapter
  • Door lock
  • BINDER test confirmation
CB 53
Exterior dimensions
Width (mm) 580
Height (incl. feet) (mm) 720
Depth (plus 55 mm for door handle and connection) (mm) 550
Wall clearance side / rear (mm) 50 / 100
Number of doors (ea.) 1
Inner glass door(s) 1
Interior dimensions
Width (mm) 400
Height (mm) 400
Depth (mm) 330
Interior volume (l) 53
Number of shelves (standard/max.) 2 / 3
Dimensions shelves width x depth (mm) 396 x 289
Load per shelf (kg) 10
Permitted total load (kg) 30
Weight (empty) (kg) 60
Temperature data
Temperature range from 5 °C above ambient temperature to (°C) 60
Temperature variation at 37 °C (± K) 0,3
Temperature fluctuation at 37 °C (± K) 0,1
Recovery time after door was opened for 30 sec. at 37 °C (min.) 1) 3
Humidity data
Humidity (±2% r.h.) 95
CO2 data
CO2 range (vol. % CO2) 0 – 20
Setting accuracy (Vol.-% CO2) 0,1
Recovery time after door was opened for 30 sec. 1)
at 5.0 vol. % CO2 (min.) 6
CO2 measurement IR
Connection hose nozzle for CO2 for hose with internal diameter (mm) 6
O2 data
O2 range (vol. % O2) 0,2 – 95
Setting accuracy (Vol.-% O2) 0,1
Recovery time after door was opened for 30 sec. 1)
at 1.0 vol. % O2 (min.) 25
at 5.0 vol. % O2 (min.) 9
O2 measurement ZrO2
Connection hose nozzle for O2 / N2 for hose with internal diameter (mm) 6
Electrical data
Voltage (± 10%) 50/60 Hz (V) 230
Nominal power (kW) 1,0
Energy consumption at 37 °C (W) 2) 70

1) up to 98 % of the set value
2) These values can be used for dimensioning air condition systems.

Technical Specification

Contact Us

+966-556111951 info@somatco.com

Visit Our Showroom

Find our Showroom/Branch Offices which is near to you

Reviews

There are no reviews yet.

Be the first to review “1833/53_CB 53”

Your email address will not be published. Required fields are marked *